                        Λεπτομέρειες:
                                                     
                
 
  | 
                    
| Μοντέλο: | Γ-HSKT10 | Μέγεθος πίνακα: | 200 X 200 | 
|---|---|---|---|
| Ανώτατο βάρος δειγμάτων (κλ): | 10 | Σφυγμός κλονισμού: | μισό ημίτονο | 
| Μέγιστη σειρά επιτάχυνσης (m/s2): | 10000g | Σειρά διάρκειας σφυγμού (κα): | 0.2~11 | 
| Εξουσία: | Ηλεκτρονικός | ||
| Επισημαίνω: | High acceleration shock test system,Electronic component shock tester,Shock test system with 200-100000G | 
					||
Mechanical Shock Test conforms to such testing specifications as GB/T2423-2008, GJB150, GJB360, GJB548, GJB1217, UN38.3, MIL-STD-202F, IEC-68-2-27, MIL-STD-810F, MIL-STD-883E, etc.
Important Features and Benefits
| Main parameters of the shock tester | |
| Operating platform | 200 × 200 mm | 
| Max. load | 10 KG | 
| Peak acceleration | 200-100000m/s2 (200 -10000G) | 
| Pulse duration | 0.2~18ms (Half sine wave) | 
| Equipment dimensions | 770×670×2750mm | 
| Equipment weight | 810 kg | 
| Dual Mass Shock Amplifier | |
| Table size | 80x150mm | 
| Max. load | 2 kg | 
| Peak acceleration | 30000G | 
| Pulse duration | 0.06—0.5ms | 
| Data analysis and acquisition systems | |
| Input channels | 4 channels | 
| Sampling frequency | 1MHz | 
| Coupled mode | AC,DC,IEPE | 
| ADC resolution | 16 bits | 
| Dynamic range | >80dB | 
| harmonic distortion | <85dB | 
| Signal to Noise Ratio | >70dB | 
| Pulse duration | Less than 0.02ms | 
| Acceleration range | Up to 100,000gn | 
| External trigger | support | 
| Interface | USB2.0 | 
| Operating system | Win10 | 
| Type | Shock acceleration sensors | 
| Model | 3200B2T | 
| Output mode | Charge type | 
| Sensitivity | 0.05 mV/g±25% | 
| Frequency range | 0.5 to 20K Hz frequency range (±10%) | 
| Acceleration range | 50000G | 
| Operating environment | -51 to +121℃ | 
| Other information | |
| Power supply | AC, three phase, 380V±10% 60Hz 5KVA | 
| Compressed air | 0.5—0.7MPa | 
| Applicable standards | GB2423.5, GJB150.18, GJB360.23,UN38.3,IEC68-2-27, MIL—STD202F, MIL-STD810B, GB/T18287, etc. | 
Customer Services
Presales:
In-Sales:
After-Sales:
![]()
![]()
Υπεύθυνος Επικοινωνίας: Mr. Labtone